Roughness conveRsion table Ra μm ISO 468 e 4287 AA μinch USA ASA B.46.1 Centre Line Average CLA μinch GB BS 1134 Rt μm Germany Rz μm JIS mean of 10 points. Hebben betrekking op de internationale standaard ISO 6123/2-1982 waarin de. Genormaliseerde waarde van ruwheid (µm) Ra Rz Ra Rz Ra Rz Ra Rz. Assuming Rz DIN verses Rz ISO Conversion factor = 7.2 Ra = Print Rz / 7.2. Convert surface finish - Rz to Ra. Rz: Ra Waarbij Ra: ±Rth:4 Blauw invullen Rood is resultaat Neusradius.
Topic 6753 Rz to Ra; Surface texture conversion (2000) Could someone please help me out with a conversion factor. I need to convert Ra to Rz. If my print states a machined surface to be controlled to a maximum of Rz125, what would be the Ra equal? My measuring equipment has parameter settings of Rz.J, Rz.I and R3z. Peavey Eurosys 500 Xt Manual. Which setting would I want if the characteristic tolerance is Rz125? Todd D [last name deleted for privacy by Editor] - Toledo, Ohio April 8, 2008 Rz (din) = Ra*7.2 Rz(ISO) = Ra*7.6 Ra=Rz(din)/7.2 Ra=Rz(ISO)/7.6 san [last name deleted for privacy by Editor] - shanghai china January 18, 2009 I want to equivalent of Rz5 in Ra value Subramani MOHAN KUMAR MACHINING - HOSUR, TAMIL NANU, INDIA This public forum has 60,000 threads. If you have a question in mind which seems off topic to this thread, you might prefer to.